MiniRAE 2000 Model PGM-7600
The MiniRAE 2000 is the world's most popular hand-held photoionization detector (PID) for volatile organic compound (VOC) measurement

KEY FEATURES
New RAE Photo-Ionization Detector (PID) 3-D sensor
Accessible lamp and sensor
Reduced humidity interference
Improved linearity, Increased sensitivity, Extended range 0 -10,000 ppm
Strong, built-in sample draw pump with pump stall feature
Sample up to 100’ (30m) horizontally or vertically
Prevents liquid flow into the monitor
Warns if sample tubing is blocked or crimped
External, field replaceable NMH rechargeable battery
10 hours of continuous monitoring
Smart battery charging
Alkaline battery holder supplied
Automotive charger available
Robust Inlet Probe
Large keys operable with 3 layers of gloves
Large easy to read back light display
Alarm activated
Darkness or manually activated
Preset alarm thresholds for STEL, TWA, low high level peak values
Audio buzzer and flashing LED display will be activated when the limits are exceeded
15,000 point data logging storage capacity for data download to PC
Rubber protective boot
102 built-in correction factors from a RAE list of 250+
chemicals
User selectable hygiene and survey modes
Protected from portable radios


[BACK TO TOP]
[VIEW PRODUCT SPECIFICATIONS,PDF]

MiniRAE Plus Classics PGM-76
The MiniRAE was the world's first hand-held, portable Photo-Ionization Detector (PID). It has proved itself rugged and reliable, withstanding environments beyond its original design specifications. The MiniRAE Plus Classic is the newest improved and simplified version of the MiniRAE VOC monitor. Durable lead-acid batteries providing continuous monitoring for up to ten hours of continuous operation. Improvements include better linearity, increased range from 0.1 - 4000 ppm, easier lamp and sensor access, faster pump, and better leak-tightness, all at a lower cost.

APPLICATIONS
Confined Space Entry
- Shipyard and maritime confined spaces
- Land-fill operations
- Trenches, silos, railcars

Waste water treatment plants

Refineries and petrochemicals plants including offshore drilling and plant shut-downs

Power plants
Pulp and paper
Steel mills
Environmental clean-up
Hazardous waste spills
Chemical process control and leak detection

KEY FEATURES
Lower Cost

Lightweight and Compact
- 18 ounces with batteries

Dependable and Accurate
- Rugged design, microprocessor control

User Friendly
- Menu driven, intuitive end-user operation
- Large easy to read back light display
- Simple calibration instructions

Functional Performance
- Extended range of 0.1 to 4,000 ppm

Mechanical Quality
- Airtight gas inlet probe and sensor
- Easier lamp and sensor access
- Easy to replace metal filter

Photovac 2020 PRO
NEW 2020PRO Photoionization Monitor

Rapid VOC detection in air, water and soil
The Photovac 2020PRO Photoionization Detector is very stable and linear. The 2020PRO is equipped standard with a 10.6 eV UV lamp, and has an optional 11.7 eV UV lamp for ionizing chlorinated compounds. The Photovac photoionization detector is also humidity-compensated so you can rely on the results under any conditions.

Effortless Data Handling
Expanded internal datalogging allows the operator to record thousands of sampling points that can be downloaded to a computer using the new 2020PRO Chart software.

Dedicated Calibration Key
Immediate access to the calibration procedure with more user prompts to easily walk you through calibration completely for higher confidence in calibration.

Easy to Use
Three modes of operation to suit your needs:

1. Non-logging – Continuous readings for survey and site checking.
2. Tagging – Data logged by tag name or number - ideal for EPA Method 21.
3. Interval Logging – Logs at pre-set intervals as well as displaying the TWA, STEL, PEAK and current reading at all times.

Intrinsically Safe
Classified as Intrinsically Safe in North America (Class I, Division 1, Groups A, B, C, and D) and Europe (EEx ib m IIC T4 and ATEX) for use in potentially explosive environments.


[BACK TO TOP]
[VIEW PRODUCT SPECIFICATIONS,PDF]

Photovac 2020 PID
The Photovac 2020 PID is ideal for the fast detection of Volatile Organic Compounds (VOCs). Weighing under 2 lbs., the Photovac 2020 is light, yet rugged. Samples are drawn in through the internal pump and results are displayed within seconds on the large, easy-to-read backlit LCD display.

Take advantage of proven technology
The 2020 operates all day long using photoionization, the technology of choice for detecting VOCs in air, soil and groundwater. The 2020 is equipped standard with a 10.6 eV UV lamp, with an optional 11.7 eV UV lamp for ionizing chlorinated compounds.

Rely on it hour after hour
Operating automatically, the 2020 will run for a full workday. When preset levels are exceeded both audible and visual alarms are activated. The complete record of the day's activity is presented in a tabular format indicating concentration vs. time. Stored data is easily downloaded to a PC using Windows® HyperterminalTM

The Photovac 2020 PID is classified as Intrinsically Safe in North America (Class I, Division 1, Groups A, B, C, and D) and Europe (EEx ib m IIC T4) for use in potentially explosive environments.

An excellent tool for monitoring toxic gases and vapors in workplace environments, the Photovac 2020 is the PID of choice.

[BACK TO TOP]
[VIEW PRODUCT SPECIFICATIONS,PDF]

Thermo 580B OVM Data Logger
APPLICATIONS
Detection of Soil and Water Contaminants

Leak Detection in Industrial Installations

Locating Spills and Leaking Underground Storage Tanks

Industrial Hygiene Monitoring

Emergency Response

KEY FEATURES
User Friendly Operation
- Single handed grip with easy keypad
accessibility
- Simplified 7 segment keypad
- LCD Output steps operator through program
- Maximum concentration signal hold facilities isolation of chemical leaks

Portable and Rugged
- Operated from internal batteries for 8 hours in the field
- Positive displacement pump enables sample collection and remote detection of organics vapors
- Requires no support gases
- Case designed for protection against hard impacts, harsh weather conditions, and
chemical interaction

Advanced Calibration Utilities
- Microprocessor based design offers simplified calibration routines
- Automatic recall of stored backup calibrations for in-field convenience
- Ability to store 4 calibrations in memory
- User settable calibration response factors

Flexible Data Logging / Retrieval

 

[BACK TO TOP]
[VIEW PRODUCT SPECIFICATIONS,PDF]

UltraRAE Specific Compound Monitor
UltraRAE is a quick, spot-check monitor, typically used by occupational health, safety and environmental personnel. The combination filter tube and PID remove the disadvantages associated with colorimetric tubes and gas chromatographs. Simply insert a RAE-Sep™ tube and get either a total vapor reading or a specific compund reading, such as benzene in petroleum vapor or methylene chloride in organic solvent vapors. Applications include tank entry pre-screening during petrochemical plant maintenance, hazardous material response, marine spill response, and refinery down-stream monitoring.

APPLICATIONS
Military
Pipelines
Crude oil production
Transportation - tankers, railways, aircraft, barges
Refineries & refinery contractors
Petroleum user - gasoline, diesel, jet fuel
Steel - light hydrocarbon by-product from coking
Petrochemical plants
Benzene solvent users
Environmental companies
HazardousMaterial (Hazmat) Response Teams

KEY FEATURES
3-16 times faster analysis time
accuracy
excellent range and linearity
internal pump
small, hand held monitor
low cost of analysis
lower cost of ownership
minimal interference
Principle of Operation
A photo-ionization detector (PID) is used for broad band screening down to very low ppm levels of volatile organic compounds (VOCs), for example, petroleum or solvent vapors. The UltraRAE not only uses traditional lamps but also a lower energy lamp (9.8 eV) for benzene monitoring (benzene ionization potential IP = 9.25 eV). A 9.8 eV lamp discriminates against other hydrocarbons with higher ionization potentials commonly found in petroleum vapors yet easily detects sub ppm levels of benzene. To screen for very low levels of potentially toxic VOCs, an empty glass tube is used. To read specific compounds, for example benzene, a patented RAE-Sep™ tube is added. This tube, containing absorbent materials, filters most of the other VOCs, such as toluene, that will interfere with the benzene reading. A RAE-Sep™ tube is simply broken at each end and inserted into the top of the monitor. By pressing the "Y" key, a strong, internal pump draws the air sample through the tube and the final result is shown on the display (after 30 to 75 seconds depending on the compound). A fresh tube is used for each measurement. These tubes also absorb humidity to allow for a very accurate reading on the UltraRAE. A bar code reader identifies the type of tube inserted. The data-logging feature then records the date and time of monitoring, the tube type, and the concentration. To obtain the accuracy at such low levels and the confidence in your results, we recommend calibration, prior to use. A simple, clean-air zero and span gas calibration takes less than 3 minutes.

 

[BACK TO TOP]
[VIEW PRODUCT SPECIFICATIONS,PDF]

ppBRAE Portable Continuous Monitor

APPLICATIONS
Weapons of Mass Destruction – chemical warfare agents
Emergency response to hazardous spills
Indoor air quality in new, sick and mixed usage buildings
Outgassing of new building materials (carpets and fabrics)
Hospital emergency room patient off gassing
Ethylene oxide, Formaldehyde
Breathe sampling
Personnel monitoring of very toxic compounds – MDI, TDI
Personal monitoring of low volatile toxic compounds
-Heat exchange fluids in petrochemical plants
-Therminol
-Pesticides and pesticide residues
Hypo-allergenic studies in chemical clean rooms
Laboratory fume hood breakthrough
Personal protective equipment (PPE)-Breakthrough, Decision making
Environmental Survey instrument
Leak detection, Residue studies
Drug detection
KEY FEATURES
New patented planar, dual channel PID detector
New super bright UV lamp
Increased sensitivity down to 1 ppb
Reduced humidity interference
Improved linearity
Easily accessible lamp and sensor
Strong, built-in sample draw pump with pump stall feature
Prevents liquid flow into the monitor
Snap-in, field replaceable NMH rechargeable battery 10 hours of continuous monitoring
Smart battery charging
Alkaline battery holder supplied
Automotive charger available
Large keys operable with 3 layers of gloves
Large easy to read back light display
Alarm activated
Darkness or manually activated
Preset alarm thresholds for STEL, TWA, low and high level peak values
Audio buzzer and flashing LED display will be activated when the limits are exceeded
15,000 point data logging storage capacity for data download to PC
Rubber protective boot
102 built-in correction factors from a RAE list of 250+
chemicals
User selectable hygiene and survey modes
Protected from portable radios

 


.

 

 
INSTRUMENTS FOR SALE I INSTRUMENTS FOR RENT I CALIBRATION SERVICES I MAINTENANCE SERVICES
MARKETING AND SALES I SPECIALS I NEWS I ABOUT US I CUSTOMER SERVICE I CONTACT INFO
CONTACT US I QUOTATIONS ONLINE I SITE MAP I CONTACT WEBMASTER


SOLUCIONES CREATIVAS
Web Division


Copyright © 2004 Lumur International, Inc.
All Rights Reserved
.